Generator Vibration Pads
Looking for heavy-duty anti vibration pads for your generator? Unick Vibration Control Systems Pvt. Ltd. manufactures and supplies generator vibration pads to help reduce vibration transfer to the supporting floor and structure. As an ISO 9001:2015 certified manufacturer, we offer Spring Pads, Cushy Foot Mounts, Sandwich Mounts and Rubber Pads for new diesel generator installations and replacement requirements.
Reduce Vibration Transfer from Your Generator to the Building
Generator vibration can travel through the base and supports into the floor and surrounding structure. You may feel it in nearby rooms even when the equipment is some distance away. Suitable anti vibration pads for generators help reduce this transmission at the support points.
Suitable pads and mounts help reduce vibration passing through the generator’s supports. They do not fix engine faults, loose parts or exhaust noise, which need separate attention.
Pads and Mounts for Generator Vibration Control
Unick Vibration Control Systems Pvt. Ltd. offers a range of vibration control solutions for generators, including spring pads, Cushy Foot Mounts, Sandwich Mounts, and rubber pads. The right solution depends on your generator’s weight, mounting arrangement, and installation location. Our team is always available to help you choose the most suitable vibration control pads or mounts for your generator.
Contact Us
Cushy Foot Mounts For Power Generators
Unick Cushy Foot Mounts combine cast iron with rubber-to-metal bonded Sandwich Mount elements. These internal elements work in compression and shear to help reduce vibration transfer from the generator to the supporting structure. These generator anti vibration mounts include anchoring provisions and an anti-skid rubber layer beneath the base for grip on the floor.
Sandwich Mounts for Generator Sets
Unick Sandwich Mounts contain rubber bonded between metal plates to help reduce vibration transfer through generator supports. Depending on their design and mounting arrangement, they can work under compression, shear or combined loads. For new installations or replacement requirements, the mount’s load rating, fixing dimensions and support function must match the generator’s requirements.
Spring Pads for Diesel Generators
Unick Spring Pads combine coil springs with viscous damping to help reduce generator vibration transfer to the surrounding structure. The springs provide flexible support, while the damping helps control excessive movement. Anti-skid plates on the top and bottom provide grip between the generator, pad and supporting floor.
AVM Pads for DG Set: New Installation or Replacement?
Whether you are installing a new DG set or replacing worn mounts, the support arrangement needs to match your generator. AVM pads for DG set installations may support the complete base frame or serve as mounts within the equipment assembly. These positions have different requirements, so the products are not automatically interchangeable.
For a new installation, follow the generator manufacturer’s mounting requirements. For replacement, share photographs of the existing mounts, part numbers and fixing dimensions so our team can help identify a compatible option.
Already Have Pads but Still Feel Vibration?
If your generator still causes floor vibration despite having pads, the existing supports may be worn, unevenly loaded or unsuitable. Connected pipes and other contact points can also carry vibration into the building. Adding thicker pads or another layer may not solve the problem.
Have the generator and its supports inspected before making changes, especially if the vibration has increased suddenly.
Benefits of Anti Vibration Mounts for Diesel Generators
Anti vibration mounts for diesel generators help support the equipment and reduce vibration reaching the floor and nearby structures. When correctly selected and installed, they can help with:
Less floor vibration:
Reduce vibration passing through the generator’s supports.
Less disturbance nearby
Reduce vibration felt in surrounding rooms.
Better movement control
Help manage generator movement during operation.
Why Choose Unick Vibration for Generator Vibration Pads?
Unick Vibration Control Systems Pvt. Ltd. manufactures generator vibration pads and mounts for different installation and replacement needs. We help you understand the available options based on your generator and the vibration problem you want to address.
ISO 9001:2015 certified manufacturer: A certified quality management system for our manufacturing operations.
Different product options: Spring pads, Cushy Foot Mounts, Sandwich Mounts and rubber pads.
Technical selection support: Guidance based on equipment weight, operating speed and mounting arrangement.
Clear product information: Dimensions, load ratings and fixing details for the proposed product.
New and replacement requirements: Support for new DG set installations and compatible replacement mounts.
Discuss Your Generator Requirement
Share Generator Photos and Get a Quotation
Frequently Asked Questions
Mechanical vibration can pass through the generator supports into the floor. The support arrangement, foundation and equipment condition all affect what you feel. Suitable isolation can reduce support-borne transfer, while any equipment fault needs separate attention.
They can help where the disturbance comes from vibration travelling through the building structure. They do not remove airborne engine or exhaust noise, which may need separate treatment.
The choice depends on the support loads, operating conditions and required isolation. Unick Spring Pads include viscous damping; rubber pads use a different support design. Neither is automatically the best option for every generator.
A compatible replacement can be assessed using the existing mount’s dimensions, fixing arrangement and equipment requirements. Send a photograph and part number where available rather than choosing by appearance alone.
No. Generators with the same output can have different weights and support layouts. The load at each mounting point and installation details are needed for a suitable recommendation.
Tell us this at the enquiry stage. The building’s load capacity and structural response need appropriate engineering review alongside the isolation system. Pads do not replace that structural assessment.